marYX3G
Multilayer mirrors
- superb multi-layer mirrros with extremely high brilliance and low divergence
- 15 cm mirror length
- vacuum pump for mirror protection
mardtb goniometer
- best combined with easymount extension
- fully automatic beam search
- fully automatic beam optimization
- continuous beam monitoring with ionization chambers
- support for large variety of detectors
Collimator
- 2 sets of motorized slits
- 2 ionization chambers for continuous X-ray readings
- experimental rotary shutter at end of collimator
Cryo device
- Oxford Cryosystems colling device (or others)
Anton Paar Primux 50
- Cu, Mo and Ag targets available
- 50 Watt
- Focal spot on anode 40 x 40 microns
Table and enclosure
- table top with steel surface
- custom sizes available
- 8 interlock doors with LED indicators
- safety interface to HV generator
- radiation safe
X-ray detector
- support for many detector types: EIGER2, PILATUS3, mar345, Rayonix SX-165, MX-225, etc.
- ideal combination: EIGER2 R 4M or PILATUS4 R 1M
Space for controllers for cryogenic devices
- controller for Oxford 700/800/1000 series
- marLiN2 liquid nitrogen refill controller
Primux controller
- controller for shutter and HV generator
- mobile app for control
Toma un generador de tubo sellado de microhaz de última generación con una óptica de alto rendimiento especialmente diseñada, añádale un goniometro mardtb y un detector de rayos X EIGER2 o un PILATUS4 o un mar345= más un crio-refrigerador, colóquelo en un armario brillante y obtendrá un sistema completo de recogida de datos de rayos X realmente potente y a la vez muy asequible - perfecto para cristalografía de monocristales, difracción de polvos, SAXS, WAXS, dispersión difusa y otros campos. No requiere instalaciones de agua ni eléctricas - encajará en cualquier lugar de su laboratorio.
Pero hay algo más: ¡olvídate de los presupuestos de mantenimiento que está acostumbrado a ver en otros lugares!
COMPONENTES
X-ray Generator: Generador de rayos X de microenfoque Anton Paar Primux 50 que funciona a 50 vatios (50 kV, 1000 mA) produciendo un punto de microenfoque con un tamaño de aprox. 40 por 40 µm en la fuente. El generador dispone de un refrigerador de agua de circuito cerrado que prácticamente no requiere mantenimiento. El generador proporciona un 50% más de fotones de rayos X utilizables en la muestra en comparación con las generaciones anteriores basadas en una fuente Incoatec IuS. |
|
Óptica de rayos X: Óptica multicapa AXO de última generación que produce un tamaño de punto en la muestra de < 150 por 150 µm FWHM. Otras configuraciones, por ejemplo para un haz paralelo, están disponibles bajo pedido. |
|
Detectores de rayos X:
|
|
Goniómetro: |
|
Refrigerador criogénico: Unidad de baja temperatura Oxford Cryosystems “Cryostream 1000” . |
|
Sistema de rellenado de nitrógeno líquido: marLiN2 automatic LN2 refill system |
|
Mesa y recinto de radiación: |
|
Aplicación móvil: Apps para iOS y Android para manejar el sistema de control de seguridad. |
HIGHLIGHTS
BAJO PRECIO
SIN SUSTITUCIÓN DE FILAMENTOS
DEPENDABLE
RENDIMIENTO
SIN INSTALACIONES ELÉCTRICAS
Todo el sistema puede utilizarse en tomas de pared trifásicas de 220/110 V con un fusible de 16 A.
SIN INSTALACIONES DE AGUA
La refrigeración del ánodo de metal líquido se realiza mediante un intercambiador de calor aire/agua que se suministra con el sistema. No es necesaria ninguna otra refrigeración por agua.
BAJO CONSUMO DE ENERGÍA
DISEÑO COMPACTO
BAJO NIVEL DE RUIDO
RENDIMIENTO
Does a micro-beam sealed-tube generator allow to evaluate the diffraction power of small crystals?
The answer clearly is: yes, it does. This is because the generator delivers a very small beam with such a high brilliance that even very small crystals sized < 50 µm will see enough X-ray photons. This is achieved by a highly optimized combination of source and optics parameters. Please read the application notes for further details!
ESPECIFICACIONES
Beam size at sample: | ≤ 160 μm FWHM at focal point |
Beam divergence: | ≤ 7.5 mrad FWHM |
Total flux: | > 1 x 109 photons/sec |
Mirror length |
15 cm |
Focal distance: | 395 mm from center of mirror |
Anode cooling: | closed circuit water-cooling |
Mirror protection: | diaphragm vacuum pump with interlock to shutter |
Active area: | 155.1 x 162.2 mm (2 x 4 modules) |
Pixel size: | 75 μm |
Frame rate: | 20 Hz (laboratory version) |
Dynamic range: | 32 bits |
Active area: | 155.2 x 162.5 mm (2 x 5 modules) |
Pixel size: | 172 μm |
Frame rate: | 5 Hz (laboratory version) |
Dynamic range: | 20 bits |
Detector surface diameter: | 345 mm |
Pixel size: | 150 μm standard or fast read-out, 100 μm upon request |
Cycle times: | 27-80 sec (depending on diameter and read-out mode) |
Dynamic range: | 17 bits (1-131000) |
Sensitivity: | 1.5 X-ray photons equivalent |
LN2 auto-refill system: | marLiN2 weight based level control |
Dimensions: | 1700 x 1000 x 800 mm (w:d:h), stainless steel |
Material: | magnetic table top and aluminum table frame |
NOTAS DE APLICACIÓN
En una segunda nota de aplicación mar.AN070207, una comparación directa entre el sistema marμX y un generador de ánodo giratorio utilizando las mismas condiciones experimentales (mismos cristales, tiempos de exposición, detector, etc.) reveló que los cristales pequeños producen datos superiores con el sistema marμX mientras que los resultados para cristales más grandes son prácticamente idénticos.
En una tercera nota de aplicación mar.AN20Jun08 comparamos el rendimiento de la óptica Xenocs FOX2D 10_30P y el último modelo de la óptica FOX3D 14_39P, que cuenta con un sustrato elipsoidal optimizado de alta precisión y una multicapa de última generación para conseguir un haz con propiedades de enfoque mejoradas y alta densidad de flujo. Con la óptica FOX3D observamos un aumento de más de 2 veces en la difracción observada en comparación con la óptica FOX2D, en particular cuando se observan cristales pequeños. Esta nueva óptica reduce de nuevo la distancia que nos separa de los modernos generadores de ánodo giratorio.
En una cuarta nota de aplicación mar.AN28Oct10 comparamos el rendimiento de la fuente Xenocs GeniX3D Cu HF funcionando a 30 W con la anterior fuente Genix Cu VHF funcionando a 50 W. La nueva fuente sustituye por completo al modelo VHF. Incorpora un nuevo tubo y una óptica de nuevo diseño. En la nota de aplicación describimos la recogida de datos de cristales de moléculas pequeñas de diversas formas y tamaños. La nueva fuente demuestra suministrar más fotones de rayos X utilizables en la muestra en el orden de magnitud de 1,5. Esto hace que la elección de una configuración de generador a pequeña escala sea aún más atractiva.
DESCARGAS
- Folleto del producto completo (pdf: 1.6 MB)
- Folleto del producto sencillo (pdf: 0.3 MB)
- Dibujo técnico de mesa y recinto de radiacion (pdf: 109 kB)
- Application note mar.AN260107 (pdf: 990 KB)
"Sulfur-SAD-phasing of hen egg lysozyme with Cu-radiation obtained in-house with a GeniX micro-beam generator" - Application note mar.AN070207 (pdf: 611 KB)
"Comparison of a conventional rotating anode generator with a Xenocs GeniX micro-beam generator" - Application note mar.AN20Jun08 (pdf: 1.6 MB)
"Comparison of the Xenocs 2D and 3D optics on a marμX data collection system" - Application note mar.AN28Oct10 (pdf: 1.9 MB)
"Comparison of the GeniX3D Cu HF beam delivery system with the GeniX Cu VHF system"